Energy storage from home to grid

Energy storage across the full range — residential powerboxes, C&I cabinets, and containerized ESS up to 2 MWh. LFP-first for safety and cycle life, UL 9540 certified.

From 5 kWh to 2 MWh, engineered as one system

Four form factors. Chemistry, BMS, thermal, and enclosure specified together.

Residential Powerboxes
5–20 kWh wall-mount units for single-family homes. AC-coupled ready for retrofit on existing solar. LFP chemistry for safety in living spaces. Stackable to 60 kWh for whole-home backup.
Spec a Powerbox
Commercial & Industrial Cabinets
50–500 kWh cabinet systems for C&I sites — demand charge management, peak shaving, and backup. Indoor or outdoor (IP54), integrated thermal management, and BMS-level monitoring.
Spec a Cabinet
Containerized Systems
500 kWh to 2 MWh in 20ft and 40ft ISO containers. DC-coupled or AC-coupled architectures. Factory-integrated liquid cooling, fire detection, and BMS. Ships ready to set, cable, and commission.
Spec a Container
Turnkey Configurations
Inverters, EMS, and fire suppression integrated at the factory. Cell through grid interconnect, handled in-house. One test report, one warranty.
Spec a Turnkey

All systems engineered in the U.S. Chemistry, BMS, thermal strategy, and certification path specified before the first cell is assembled.

UL 9540 is the baseline, not the ceiling

Every ESS is engineered to the North American system standard, fire-tested to UL 9540A, and sited to NFPA 855.

UL 9540 System Certification
The ESS system standard for North America. Full certification path runs in-house — test planning, lab coordination, documentation — so the project is AHJ-ready at ship.
UL 9540A Fire Propagation Testing
Cell, module, and unit-level thermal runaway testing — required for most commercial and utility installs. Test plan and report delivered before construction starts.
NFPA 855 Compliant
Spacing, siting, and fire protection requirements met out of the box. Enclosure placement, egress, detection, and suppression designed against the current code so permitting doesn't stall.

Numbers, not adjectives

Baseline specifications across the ESS line. Chemistry and capacity tuned to your duty cycle on every program.

Chemistry
LFP (primary) · NMC available
Round-trip Efficiency
95%+
Cycle Life
6,000+ at 80% DOD
Operating Temp
-20°C to 50°C
Warranty (Standard)
10 years
Warranty (Extended)
15 years
Capacity Range
5 kWh – 2 MWh
Certifications
UL 9540 · UL 9540A · NFPA 855

Tell us the site, the load, and the cycle

Send the application — grid-tied, behind-the-meter, islanded, or hybrid. Back comes a chemistry, capacity, enclosure, and certification-path spec.

Start an ESS Project